EN
59
Swegon reserves the right to alter specifications.
DISPLAY
The settings made from this menu are time
settings, with the exception of the screen
settings.
Adjustable characteristics are:
Language.
Brightness is standby mode. Adjusting
this value can affect how much the screen
brightness dims when entering standby
mode. If the value is set to 10, the bright-
ness is not dimmed at all.
Show time. Selected if the time is to be
displayed on the basic screen.
Show room temperature. Selected if the
room temperature is to be displayed on
the basic screen.
Fine adjustment of the room tempera-
ture. If, for example, the temperature
measured on panel differs from the value
from a temperature sensor installed in a
different location in the same room, the
temperature sensor can be calibrated by
changing the room air fine tuning value.
Panel’s ID number. If two panels are
installed in the system, one is given the ID
value 1 and the second the ID value 2. Two
panels with the same ID number cannot be
used in the system.
Clock.
Weekday.
Selection of standby mode. If the “NOT
Used” option is selected for “Screen
saver”, the screen goes dark, and
Display
Language
Standby brightnes
Show clock
Show room temperature
5
Room temperature fine tuning
0,0°C
Display ID
Time
Day
Screen saver
Screen saver delay
Reset display settings
10:26
1
Monday
60s
2.5 Main menu
ALARM
This menu is empty when the unit is operating
normally. If there is an active fault state in the
system, an associated alarm text is displayed
on this menu (see “Alarm”).
If there has been a disruption in the system,
but this has disappeared, the menu shows a
message that can be acknowledged. An ac-
tive alarm cannot be acknowledged (see 3.1,
”Alarms”).
TEMPERATURE
The temperature setting is only available
in models that are equipped with the air
heater for reheating.
The user sets the required value for minimum
supply air temperature, and the ventilation
unit then strives to reach this temperature if
possible. Swegon recommends that the supply
air temperature is set between 15–20 °C and
the factory setting is 17 °C, which is sufficient
for draught-free ventilation. The supply air
temperature should be 3–4 °C lower than
the room temperature, so that the supply air
mixes fully with the room air.
Remember the following when setting the
supply air temperature:
A high temperature setting will also
increase the ventilation unit’s power
consumption.
A low temperature setting, for example,
14 °C, can cause condensation to collect in
the system.
The ventilation unit cannot cool the supply
air without an air cooler (duct coil), which
is available as an accessory.
Commissioning and setting the external air
heater/air cooler, available as optional equip-
ment, are described in the installation, opera-
tion and maintenance instructions for the air
heater/air cooler.

Table of Contents

Other manuals for Swegon CASA W3 Smart

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Swegon CASA W3 Smart and is the answer not in the manual?

Swegon CASA W3 Smart Specifications

General IconGeneral
BrandSwegon
ModelCASA W3 Smart
CategoryFan
LanguageEnglish

Related product manuals