CONNECTING SERVICES
Fault Cause Remedy
Water flows from hot
tap but has reduced
flow from cold
Cold water pipe kinked preventing
flow
Blockage in cold pipe line
Cold tap not connected
Cold tap failed or blocked
Check and re-route if necessary
Disconnect pipes after 1st
connector and check up to tap
Refer to installation instructions
Disconnect and inspect
Reduced flow from
both hot and cold
taps
Battery condition low causing pump
to run slowly
If new taps have been fitted they
may be restricting flow
Pump needs servicing
Partially blocked pump filter or in-
line filter, if fitted
Pump outlet pipe kinked restricting
flow
Water leak
Check battery state of charge, refer
to electrical supply note
Disconnect and check that they have
at least 1/4” (6.3mm) bore
Refer to pump servicing instructions
Dismantle and clean if necessary
Check and re-route if necessary
Check all water connections
Reduced flow from
either tap
Pipe kinking restricting flow
Bore size difference in taps
Check and re-route if necessary
Use taps of equal bore size
If pump motor runs
steadily and will not
stop
Battery voltage may be too low
(below 10.5 volts)
Check that there is water in the
container
Adjust switch and/or re-charge
battery. Check all connections in
pipework