Object 0x1008 : Manufacturer device name
This object contains the short name of the device type.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
1008
Manufacturer
device name
Variable
Visible string
const
no
Check if
segmented
(normal)
transfer is
supported
Object 0x1010 : Store parameters
This object can be used to save the current application parameters to the frequency inverter.
Subindex 0 indicates the number of the highest supported sub-index.
Subindex 3 can be used to save the current manufacturer parameters. Writing the value 0x65766173
(hexadecimal representation of "save") to this sub-index initiates the storing of the content of object 0x3000
and all sub-index are written to the EEPROM.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
1010
Store parameters
Array
1010:00
Highest sub-index
supported
Variable
Unsigned8
const
no
3
1010:03
Save application
parameters
Variable
Unsigned32
rw
no
0
Object 0x1011 : Restore default parameters
This object can be used to write the default parameters to the frequency inverter.
Subindex 0 indicates the number of the highest supported sub-index.
Subindex 3 can be used to restore the factory defaults for manufacturer parameters. Writing the value
0x64616f6c (hexadecimal representation of "load") to this sub-index initiates the reset of the content of
object 0x3000 and all sub-index are reset to factory default settings.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
1011
Restore default
parameters
Array
1011:00
Highest sub-index
supported
Variable
Unsigned8
const
no
3
1011:03
Restore application
default parameters
Variable
Unsigned32
rw
no
0
Object 0x1014 : COB ID EMCY
This Object defines the COB-ID of the emergency object (EMCY).
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
1014
COB ID EMCY
Variable
Unsigned32
ro
no
Node-ID +
0x80
Object 0x1015 : Inhibit Time Emergency
This object indicates the minimum amount of time that must pass before another EMCY is sent.
Writing the value 0 deactivates delayed sending.
With delayed transmission, the entries are written to a queue. The queue is limited to a maximum number of
fast consecutive EMCYs (20 entries). If this number is exceeded, an EMCY is sent immediately, indicating the
overflow.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
1015
Inhibit Time
Emergency
Variable
Unsigned16
rw
no
0x0