8
Object 0x1008 : Manufacturer device name
This object contains the short name of the device type.
Check if
segmented
(normal)
transfer is
supported
Object 0x1010 : Store parameters
This object can be used to save the current application parameters to the frequency inverter.
Subindex 0 indicates the number of the highest supported sub-index.
Subindex 3 can be used to save the current manufacturer parameters. Writing the value 0x65766173
(hexadecimal representation of "save") to this sub-index initiates the storing of the content of object 0x3000
and all sub-index are written to the EEPROM.
Highest sub-index
supported
Save application
parameters
Object 0x1011 : Restore default parameters
This object can be used to write the default parameters to the frequency inverter.
Subindex 0 indicates the number of the highest supported sub-index.
Subindex 3 can be used to restore the factory defaults for manufacturer parameters. Writing the value
0x64616f6c (hexadecimal representation of "load") to this sub-index initiates the reset of the content of
object 0x3000 and all sub-index are reset to factory default settings.
Restore default
parameters
Highest sub-index
supported
Restore application
default parameters
Object 0x1014 : COB ID EMCY
This Object defines the COB-ID of the emergency object (EMCY).
Object 0x1015 : Inhibit Time Emergency
This object indicates the minimum amount of time that must pass before another EMCY is sent.
Writing the value 0 deactivates delayed sending.
With delayed transmission, the entries are written to a queue. The queue is limited to a maximum number of
fast consecutive EMCYs (20 entries). If this number is exceeded, an EMCY is sent immediately, indicating the
overflow.