3. Lubrication System
3-2
Precautions in Operation
General Information:
This chapter contains maintenance operation
for the engine oil pump and gear oil
replacement.
Specifications
Engine oil quantity Disassembly: 1400 c.c.
Change: 1200c.c.
Oil viscosity SAE 10W-30 (Recommended
King serial oils)
Gear oil Disassembly: 180c.c.
Change: 170c.c.
Gear oil viscosity SAE 140
(Recommended SYM Hypoid gear oils)
Unit: mm
Items
Standard (mm)
Limit (mm)
Oil pump
Inner rotor clearance
0.15
0.20
Clearance between outer rotor and body
0.15~0.20
0.25
Clearance between rotor side and body
0.04~0.09
0.12
Torque value
Torque value oil strainer cap 1.3~1.7kgf-m
Engine oil drain bolt 3.5~4.5kgf-m
Gear oil drain bolt 1.1~1.5kgf-m
Gear oil join bolt 1.0~1.4kgf-m
Oil pump connection screw 0.1~0.3kgf-m
Troubleshooting
Low engine oil level
Oil leaking
Valve guide or seat worn out
Piston ring worn out
Low oil pressure
Low engine oil level
Clogged in oil strainer, circuits or pipes
Oil pump damage
Dirty oil
No oil change in periodical
Cylinder head gasket damage
Piston ring worn out