3. Lubrication System
3-2
Engine Oil
Turn off engine, and park the vehicle in a flat
surface with main stand.
Check oil level with oil dipstick
Do not screw the dipstick into engine as
checking.
If oil level is nearly low level, fill out
recommended oil to upper level.
Oil Change
Caution
Place an oil pan under the vehicle, and remove
oil drain bolt.
After draining, make sure washer can be
re-used. Install oil drain bolt.
Torque value: 1.1~1.5 Kgf-m
Fill out engine oil (oil viscosity SEA 10W-40).
Recommended using King serial oil.
Install dipstick, start the engine for running
several minutes.
Turn off engine, and check oil level again.
Check if engine oil leaks.
Engine Oil Strainer Clean
Drain engine oil.
Remove oil strainer and spring.
Clean oil strainer.
Check if O-ring can be re-used.
Install oil strainer and spring.
Install oil strainer cap.
Torque value: 1.3~1.7 Kgf-m
Add oil to crankcase (oil viscosity SAE 10W-40)
Recommended using King serial oil.
Drain oil as engine warmed up so that to
make sure oil can be drained smoothly and
completely.
Drain bolt