Installation, Operations, and Maintenance Manual
Manuel d’installation, de fonctionnement et de maintenance
ATMO™ Series
Fresh Air Appliance (FAA)
Appareil à air frais (AAF)
Literature Item #: 463913
Rev date: 07-26-2023
No. d'article #: 463913
Date de revision: 07-26-2023
Your ventilation system should be installed in conformance with the appropriate provincial requirements or, in the absence of
such requirements, with the current edition of the National Building Code, and / or ASHRAE’s “Good Engineering Practices”.
Votre système de ventilation doit être installé conformément aux exigences de la province où vous habitez ou, à défaut de
telles exigences, conformément à l’édition actuelle du Code national du bâtiment du Canada ou aux « méthodes d’ingénierie
appropriées » de l’ASHRAE.
Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs,
components and specifications to maintain their technological leadership position.
Please visit our website www.fantech.net for more detailed technical information.
Fantech se réserve le droit de modifier partiellement ou entièrement, en tout moment et sans préavis, les
caractéristiques, la conception, les composants et les spécifications de ses produits, afin de conserver sa
position de leader de technologie.
S'il vous plaît visitez notre site siteweb www.fantech.net pour des informations techiques plus détaillées.
United States
10048 Industrial Blvd., Lenexa, KS, 66215
Tel.: 800.747.1762 • Fax: 800.487.9915
Canada
50 Kanalflakt Way, Bouctouche, NB, E4S 3M5
Tel.: 800.565.3548 • Fax: 877.747.8116
PARTS IN THE BOX
Fresh Air Appliance, 1 pc
Hanging Chain Kit, 1 pc
Hardware Kit, 1 pc
Drain Hose Kit, 1 pc
External Damper Wire harness, 1 pc
Operation and Installation Manual, 1 pc
PIÈCES DANS LA BOÎTE
Appareil à air frais, 1 pc
Kit de suspension, 1 pc
Vis et matériel d'assemblage, 1 pc
Tuyau d’évacuation, 1 pc
Faisceau de câbles de clapet externe, 1 pc
Manuel d'installation, 1 pc
ATMO 150H
is not
ENERGY STAR
listed.

Questions and Answers

  • A
    adam40Aug 19, 2025
    How to stop persistent condensation on windows with SystemAir Fan?
    • A
      Amy TaylorAug 20, 2025
      To address persistent condensation on windows when using your SystemAir Fan: * Reduce the desired level of humidity if there was an improper adjustment of the dehumidistat control; combine this step with the use of continuous exchange mode. * Have a contractor balance FAA if FAA is out of balance. * Open curtains or blinds if there is poor air circulation near windows.
  • T
    Tara WoodsAug 25, 2025
    Why does the supply air feel cold from my SystemAir Fan?
    • K
      Kristin BrooksAug 25, 2025
      The supply air from your SystemAir Fan may feel cold due to several reasons: * Locate the grilles high on the walls or under the baseboards, install ceiling-mounted diffuser or grilles so as not to directly spill the supply air on the occupant (e.g., over a sofa) if there is a poor location of supply grilles, the airflow may irritate the occupant; you can also turn down the FAA supply speed. * If the outdoor temperature is extremely cold and supply air is ducted into the furnace return, the furnace fan may need to run continuously to distribute ventilation air comfortably.
  • J
    Janet JohnsonAug 27, 2025
    How to fix air that is too dry with SystemAir Fantech ATMO Fan?
    • G
      goulddianaAug 28, 2025
      If the air is too dry when using your SystemAir Fan: * Increase the desired level of humidity if the dehumidistat control is set too low. * Change ventilation mode from continuous mode to standby if the dehumidistat control is set too low.
  • G
    Gary LaneAug 31, 2025
    What to do if FAA and/or ducts are frosting up in SystemAir Fantech ATMO Fan?
    • T
      Tanya WallaceAug 31, 2025
      If the FAA and/or ducts are frosting up in your SystemAir Fan: * Have an HVAC contractor balance the FAA airflows if FAA airflows are improperly balanced. * Note that minimal frost build-up is expected on the core before unit initiates defrost cycle functions if there is a malfunction of the FAA defrost system.
  • J
    Jeffery WalkerSep 4, 2025
    Why is there condensation or ice build-up in the insulated duct to the outside of my SystemAir Fan?
    • L
      Lindsey BensonSep 4, 2025
      If you notice condensation or ice build-up in the insulated duct to the outside of your SystemAir Fan, it could be due to: * Tape and seal all joints if there is an incomplete vapor barrier around the insulated duct. * Tape any holes or tears made in the outer duct covering and ensure that the vapor barrier is completely sealed if there is a hole or tear in the outer duct covering.
  • D
    David CrawfordSep 8, 2025
    What to do if no power is being transmitted to the control board of SystemAir Fantech ATMO?
    • J
      Julie ParkSep 8, 2025
      If no power is being transmitted to the control board of your SystemAir Fan: * Make sure the unit is plugged. * The transformer may need replacing.
  • E
    eddiemedinaNov 11, 2025
    How to improve poor air flow in my SystemAir Fantech ATMO Fan?
    • S
      Stephanie GomezNov 11, 2025
      To improve poor air flow in your SystemAir Fan, consider the following: * Clean exterior hoods or vents if the 1/4" (6mm) mesh on the outside hoods is plugged. * Remove and clean the filter if filters are plugged. * Remove and clean the core if the core is obstructed. * Check and open indoor grilles if they are closed or blocked. Also, have an electrician check the supply voltage if there's an inadequate power supply at the site, check duct installation if the ductwork is restricting airflow. Increase the speed of the FAA (i.e. change unit control from REDUCED to NORMAL speed) if there is an improper speed control setting. Have a contractor balance FAA airflows if FAA airflow is improperly balanced and have a contractor reconnect ducting if ducting has fallen down or been disconn...
  • T
    tmartinezNov 15, 2025
    What to do if the air is too humid when using SystemAir Fan?
    • A
      anna06Nov 15, 2025
      If the air is too humid when using your SystemAir Fan, there are several potential causes and solutions: * Reduce the desired level of humidity if the dehumidistat control is set too high; combine this with the use of continuous exchange mode. * Wait until outside temperature stabilizes (winter) if there was a sudden change in temperature. Heating will also improve the situation. * Store a majority of your wood outside if storing too much wood for heating. * Make sure the dryer vent is exhausting outside if the dryer vent exhaust is inside home. * Open curtains or blinds if there is poor air circulation near windows. * Open the door or install a grill on the door if a well-sealed basement door is closed. * Check the defrost damper; if the damper is always blocking incoming f...

SystemAir Fantech ATMO Series Specifications

General IconGeneral
BrandSystemAir
ModelFantech ATMO Series
CategoryFan
LanguageEnglish

Related product manuals