Resetting to default settings |
5
Note:
The SAVE CONNECT module is not allowed to connect to unprotected networks!
Make sure your selected Wi-Fi network has a password.
If the Wi-Fi network list do not appear or application shows an error, check
application permissions in the device settings.
4. Quit the mobile application and connect to your usual Wi-Fi.
5. Proceed to chapter 5 First login to SAVE CONNECT application for login instructions.
3 Resetting to default settings
In case of connection failure, the SAVE CONNECT module have to be reset. Disconnect the
power supply cable, press and hold the activation button and while it is pressed, recon-
nect power supply cable. The red LED will start blinking, wait until it stops blinking (~10
seconds) and then release the activation button.
4 LED indicator codes
WLAN
Ethernet Cloud
RED LED GREEN LED
Connected
Not Connected Blinks fast
Disconnected
Disconnected Blinks slow
Connected
Connected
Blinks slow
Connected Not Connected
Blinks fast
Disconnected Disconnected
Blinks fast
Connected Connected
Blinks slow
Fast blinking every 500 milliseconds. Slow blinking every 2 seconds.
5 First login to SAVE CONNECT application
Download and install SAVE CONNECT mobile application on your device.
Application is available for both Android and iOS operating systems.
Application also be accessed directly through the website (https://homesolutions.sys-
temair.com) by using any web browser.
Change language if necessary by pressing the language icon in the top right corner.
Create new account if you do not have one and follow the steps in the mobile
application.
6 Setting the SAVE CONNECT module to Modbus TCP converter mode
The SAVE CONNECT module is configured to work in a Cloud mode by default allowing
the customer to connect to the SAVE unit using the mobile application. Alternatively, it
can be switched to a Modbus TCP converter mode. This change can be done in the SAVE
CONNECT module interface.
254977 | v6