BLACK
NOIR
RED
ROUGE
BLUE
BLEU
GREEN/YELL.
VERT/JA.
PURPLE
VIOLET
SCHWARTZNEGRO
ROTROSSO
VIOLETTVIOLA
BLAUBLU
BK
RD
BU
GNYE
VT
NERO
ROJO
AZUL
GIALLO/V. GRUN/G. VERDE/AM.
VIOLETA
ORANGE
EGNAROEGNARO NAJANJA ENOICNARARO
WHITE
SSIEWCNALB BLANCO OCNAIBHW
BROWN
NUARBNURB MARRON ENORRAMNB
GREY
UARGSIRG GRIS OIGIRGYG
* ALIMENTACION PAR 230V-LA CALEFACCION DEBE FUNCIONAR
* ALIMENTER EN 230V ET ASSERVIR A LA VENTILATION
* CONNECT TO 230V PHASE-HEATER MUST RUN WITH FAN
CON EL VENTILADOR EN MARCHA
* COLLEGHI ALLA 230V-IL RISCALDATORE DEVE FUNZIONARE
CON IL VENTILATORE
* VERBINDUNG MIT 230V-HEIZUNG MIT VENTILMOTOR ARBEITEN MUSS
(2) FADEN, ES "6" ANZUSCHLIE IST VF/VCH-24V
(2) INFILI COLLEGARE IN "6" SI VF/VCH-24V
(2) HILO PARA CONECTARLO "6" SI VF/VCH-24V
(2) WIRE TO BE CONNECTED ON "6" IF VF/VCH-24V
(2) FIL A CABLER EN "6" SI VF/VCH-24V
*
*
MOTEUR DE VANNE LINEAIRE 3 POINTS-24V
3 POSITION LINEAR VALVE-24V
3 POSIZIONI PER VALVOLE LINEARI-24V
ACTUADORES LINEALES A 3 PUNTOS-24V
3 PUNKT ANSTEUERUNG-24V
SE 4546 D
230V
50/60 Hz
GNYE
CODE : 3991420
BU
GMV1
1/N 2/L
3 4
5
1/N
7
8
7
YE
8
1/N
6
8
1/N
2/L
FANCOIL BORNIER
S1-S5 LOW-MAX SPEED
GMV1/2 FAN MOTOR
M TERMINAL STRIP
OPTIONS
FCM MANUAL THERMOSTAT
ECH ELECTRIC HEATER
VF COOLING/HEATING VALVE
VCH HEATING VALVE (4 pipe)
GMV1/2 GROUPE MOTO VENTILATOR GMV1/2 MOTOR VENTILACION
GMV1/2 VENTILATORMOTOREINHEIT
S1-S5 MINIMA-MASSIMA VELOCITA
S1-S5 BAJA-ALTA VELOCIDAD
S1-S5 NIEDRIGE-HOCHE DREHZAHL
M MORSETTI SCATOLA ELECT.
M BORNERA DE CONEXION
M KLEMMLEISTE
OPZIONI
OPCIONES
OPTIONEN
FCA TERMOSTATO AUTOMATICA
FCA TERMOSTATO AUTO
FCA UBERHITZUNGSSCHUTZ
ECH RESIST. RISCALDAMENTO
ECH RESISTANCIA CALEFACCION
ECH HEITZUNGWIDERSTAND
VF VALVOLA ESTATE/INVERNO
VF VALVULA FRIO/CALO
VF KALTWASSERSCHIEBER/WARMWASSERSCHIEBER
VCH VALVOLA INVERNO (4 tubi)
VCH VALVULA CALO (4 tubos)
VCH WARMWASSERSCHIEBER (4 rohren)
F GENERAL PROTECTION
F PROTEZIONE GENERALE
F PROTECCION GENERAL
F ALLGENEIMER SCHUTZ
FCA AUTO THERMOSTAT
FC
M SEGUREZZA MANUALE
FCM SEGURIDAD MANUAL
FCM HANDUBERHITZUNGSSCHUTZ
S1 … S5 PETITE … GRANDE VITESSE
GMV1/2 GROUPE MOTEUR VENTILATEUR
M BORNIER DE RACCORDEMENT
F PROTECTION GENERALE
OPTIONS
FCM SECURITE MANUELLE
ECH ELEMENT(S) CHAUFFANT(S)
VF MOTEUR DE VANNE-EAU FROIDE/CHAUDE
VCH MOTEUR DE VANNE-EAU CHAUDE(4T)
FCA SECURITE AUTOMATIQUE
9 10
BU
BN
BN
BU
BN
BU
BK
BU
BN
BN
BK
BK
BU
OPTION SCH MONTE
(POUR THERMOSTAT TAE20)
MODELE/MODEL/MODELLO/
MODELO/MODELL
2T2F/2T2F+CHANGE-OVER
ASSEMBLED OPTION SCH
(FOR TAE20 ROOM THERMOSTAT)
OPZIONE SCH MONTANA
(PER TAE20 TERMOSTATO)
OPCION SCH SUBIDA
(PARA TAE20 TERMOSTATO)
AUFGERICHTETE OPTION SCH
(FUR THERMOSTAT TAE20)
M
KR RELAIS DE CHAUFFAGE
SW/
SCH SONDE DE TEMPERATURE D'EAU
KR HEATER RELAY
SW/SCH WATER TEMPERATURE SENSOR
KR RELE DI RISCALDAMENTO
SW/SCH SONDA DI TEMPERATURA DELL AQUA
KR RELE DE CALEFACCION
SW/SCH SONDA TEMPERATURE AGUA
KR RELAIS ELEKTROHEIZUNG
SW/SCH WASSER TEMPERATURESONDE
*
*
*
230V +
BU
BN
N
PH
BU
BK
WH
BN
10/20
S 5
S 4
S 3S 2
RD
BN
VT
GY
BK
40
TAILLE
WH
RD
(2)
SM OPTION SONDE DE MINIMA
SM MINIMUM TEMPERATURE SENSOR OPTION
SM OPZIONI SONDA DI TEMPERATURE MINI
SM OPCIONES SONDA
DE TEMPERAURE MINI
SM OPTIONEN TEMPERATURE-SONDE MINI
6
BU
BU
6
(2)
BU
(2)
(2)
(2)
9
BU
BK
WH
BN
2T2F+CHANGE-OVER
9
7
BN
9
BU
BK
WH
MODELE/MODEL/MODELLO/
MODELO/MODELL
2T2F+KR /2T2F+KR+CHANGE-OVER
*
MP POMPE DE RELEVAGE CONDENSAT
SB1 NIVEAU MARCHE MP
SB2 NIVEAU DEFAUT CONDENSAT
SB1 WATER LEVEL SENSOR MP ON
SB2 WATER LEVEL SENSOR ALARM
MP CONDENSATE PUMP
MP MOTORE POMPA CONDENSATO
SB1 SENSORE DI LIVELLO ACQUA MACIA MP
SB2 SENSORE DI
LIVELLO ALLARME
MP MOTOR BOMBA CONDENSADOS
SB1 CAPTAD
OR DE NIVEL DE AGUA MP
SB2 CAPTADOR DE NIVEL DE AGUA ALARMA
MP MOTORPUMP KONDENSAT
SB1 WASSERSTANDMESSFUHLER MP EIN
SB2 WASSERSTADMESSFUHLER ALARM SIGNAL
C V
BN
GN
BU
BU
WH
RD
RD
OG
VT
GY
BN
GNYE
BU
GMV2
TV
M
M
RD
BN
OG
VT
GY
BK
1
6
L
60/70
GMV
GMV1
GMV2
GMV1
OG
BN
VT
GY
BK
RD OG
VT
GY
BK
RD
WH
WH
BK
KR
TV AUTOTRANSFORMATEUR MOTEUR GMV1
TV AUTOTRANSFORMER FAN MOTOR GMV1
TV SPARTRANSFORMATOR LUFTMOTOR GMV1
TV AUTOTRANSFORMATORE MOTORE GMV1
TV AUTOTRANSFORMADOR MOTOR GMV1
RD
30
GMV1
S 1
OG BN
VT
GY BK
80
GMV1
RD
BN
VT GY BK
N/1
L/2
MP
SB1
BN
BU
GNYE
L
N
C
NC
SB2
NEUTRE MOTEUR/SERVOMOTEUR(S)
/CHAUFFAGE ELECTRIQUE
(1000W max)
GY
NO
BK
MODELLO/MODELO/MODELL
2T/2T+CHANGE-OVER/4T
VF
VCH
11 12 13 14 15 16
WH
WH
BN
BN
GN
GN
o
p
e
n
o
p
e
n
com
com
c
l
o
s
e
c
l
o
s
e
*
*
**
VF
12 13
11
WH
BN
GN
o
p
e
n
com
c
l
o
s
e
*
*
VF
12 13
11
WH
BN
GN
o
p
e
n
com
c
l
o
s
e
* *
GN/YE
50
GMV2
BN OG
VT
GY
BK
N/1
L/2
MP
SB1
BN
BU
GNYE
L
N
C
NC
SB2
VERSION CONTACT SEC RETIRER
LE SHUNT ENTRE C ET N
SB2 DOIT COUPER GMV+VF
NO
HD
DRY CONTACT VERSION REMOVE
THE SHUNT BETWEEN C AND N
SB2 MUST CUT GMV+VF
!
!
>
>
>
>
VF
VCH
T <
S W
VF
T <
SW
FCM
FCA
ECH
VF
T <
SW
ECH
FCA
A2
A1
KR
SCH
SM
11
14
21
24
FCM
1
2
3
4
F
IXSYSCOIL COMFORT
APPENDIX / ANNEXE / ANLAGE / ALLEGATO / ANEXO
SE 4546 - SYSCOIL COMFORT AC MOTOR TERMINAL BLOCK