96 General Information TB7100 Service Manual
© Tait Electronics Limited October 2005
331 – Final bias 1
Sets or reads the bias voltage for
the first PA
331 (to read value) x
where x is the DAC value of the
bias voltage (an integer from 0 to
255)
331 x (to set value)
where x is the DAC value of the
required bias voltage
(any integer from 0 to 255)
None
332 – Final bias 2
Sets or reads the bias voltage for
the second PA
332 (to read value) x
where x is the DAC value of the
bias voltage (an integer from 0 to
255)
332 x (to set value)
where x is the DAC value of the
required bias voltage
(any integer from 0 to 255)
None
Table 6.6 CCTM commands in the transmitter category
Command
Usage
Entry at keyboard Response on screen