12 Description TB7300 Installation and Operation Manual
© Tait International Limited December 2022
Upgrading from a PC using Mongoose as the local feed server from version
3.05 or earlier will display 2 versions for version 3.10 and later. The
version ending in ‘-02’ is series 2 reciter firmware:
Attempting to download -02 firmware to a series 1 reciter will fail, with a
status of ‘Error’ within a few seconds.
Upgrading from a PC using Mongoose as the local feed server with a reciter
running version 3.10 or later will select the correct firmware package for
the reciter automatically. The list of firmware presented in the lower
section is filtered by the P25/AS-IP, DMR/MPT or All radio buttons at the
top of the Tools > Firmware > Upload/Download tab WebUI page.
If you are using the direct firmware upload option, the series 1 firmware
file has the suffix
.tbc and series 2 has the suffix .tbc02. File selection
has a filter for the correct file extension.
Uploading the incorrect firmware version for the series of reciter will fail
with the message ‘Information Failed Configuration’ in the Direct upload
section.