36 Base Station Specifications TB9400 Specifications Manual
© Tait Limited July 2017
1.9.4 Heat Load Values
These measurements were carried out with the base station transmitting at
its rated output power with all front panel fans running. All measurements
were carried out with no load on the auxiliary power supply.
1.9.5 Dimensions and Weight
1.9.6 Reliability
WBtu/h
Base station
a
Single 50W
Dual 50W
100W
185W
340W
295W
631Btu/h
1160 Btu/h
1007Btu/h
a. Transmitting at rated output power.
Dimensions
Height
Width
Length
Subrack only
Including front panel
176.8mm (7in)
482.6mm (19in)
385mm (15.2in)
400.5mm (15.8in)
Weight
a
Single 50W Base Station
Dual 50W Base Station
100W base station
Receive-only
1 receiver
2 receivers
3 receivers
4 receivers
19.6kg (43.2lb)
24.8kg (54.7lb)
21.1kg (46.5lb)
16.9kg (37.3lb)
19.3kg (42.5lb)
21.7kg (47.8lb)
24.1kg (53.1lb)
a. With AC and DC PMU.
MTBF >80,000 hours (based on field returns)