TM8100/TM8200 Service Manual General Information 123
© Tait Electronics Limited June 2006
Table 4.7 CCTM commands in the transmitter category (part 2)
Command
Usage
Entry at keyboard Response on screen
Transmitter category
331 – Final bias 1
Sets or reads the bias voltage for
the first PA
331 (to read value) x
where x is the DAC value of the
bias voltage (an integer from 0 to
255)
331 x (to set value)
where x is the DAC value of the
required bias voltage
(any integer from 0 to 255)
None
332 – Final bias 2
Sets or reads the bias voltage for
the second PA
332 (to read value) x
where x is the DAC value of the
bias voltage (an integer from 0 to
255)
332 x (to set value)
where x is the DAC value of the
required bias voltage
(any integer from 0 to 255)
None