Normal Operaon
Owner's Guide
NORMAL OPERATION
BUILT-IN CONTROLLER and REMOTE CONTROLLER

1. Open a cold water
fixture.
2. Mix hot water with the cold water
to get the correct temperature water.
3. When finished, close the
water fixtures.
 Flow rate to activate the water heater: 0.5 gallon per minute at the default set
temperature (1.9 L/min.)
 Flow rate to keep the water heater running: 0.4 gallon per minute (1.5 L/min.)
NOTICE
GENERAL
Built-in controller Remote controller
6 75
1
8
2
3
4
9
6 85
2
3
9
174
No. Description Note No. Description Note
1
"ON/OFF"
Button
Press this button to start or stop
operation.
5
"TIME"
Button
Press this button to set the
current time.
2
"HOT"
Button
Press the "HOT" button or the
"COLD" button to set the outlet
water temperature, the current
time, and PUMP TIMER.
6
LCD
The current time, set temperature,
error code and other information
are displayed.
3
"COLD"
Button
7
"PUMP"
Button
Press this button to set and con-
trol the pump operation.
4
"INFO."
Button
Press the "INFO." button to dis-
play the inlet & outlet water tem-
perature and water flow and set
the outlet temperature, pump
choosing, and unit conversion.
8
IN USE LED
The LED lights during combustion.
9
STAND BY LED
The LED lights when power is on.
Temperatures above 125 °F (52 °C) can cause severe burns or death from scalding.
Children, disabled and the elderly are at high risk of being injured.
WARNING
°F 120 125 130 135 140 145 150 155
°C 49 52 54 57 60 63 66 68
Time to produce
serious burn
more
than 5
min.
to 2
min.
about
30 sec.
about
10 sec.
less than
5 sec.
less than
3 sec.
about
sec.
about
1 sec.
 When the remote controller is installed it will take priority over the built-in controller.
 The controller has an energy saving mode. Five minutes after the water heater stops
operating, the backlight of the controller turns off.
 The backlight of the remote will turn back on once the water heater begins firing again.
NOTICE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Takagi 540P Indoor and is the answer not in the manual?

Takagi 540P Indoor Specifications

General IconGeneral
BrandTakagi
Model540P Indoor
CategoryWater Heater
LanguageEnglish

Related product manuals