20
D749MA
7
2
nd
RADIO
CHANNEL
On
2 sec. monostable function: when the impulse from the remote
Off
Active bistable function: when the impulse from the remote control
following impulse.
8
MOTORS
SELECTION
On
Off
9-10-11 Automation type selection
Dip 9 Dip 10 Dip 11 Automation
Off Off Off
On Off Off
Off On Off
On On Off R40
Off Off On
On Off On not used
Off On On not used
On On On not used
IMPORTANT: In case the automation type change, a new setting of the dips # 9,
10 and 11 will be required. Before the new setup, however, IT IS NECESSARY TO
PROCEED TO A HARD RESET of the controller.
12
SENSITIVE
EDGE
On
Off
MEMORIZATION PROCEDURE
WARNING: After powering the control panel, wait 2 seconds before you start performing
the adjustment operations.
Note: the mechanical stops of the automation must be regulated both in opening and in
closing [see motor instructions].
Check the position of dip-switches 9, 10 and 11. Dip-switches must be set according
to the automation model (see table of dip-switches 9-10-11, “Logic adjustments”
section).
Note: if the automation does not work, check the input connections. The DL6, DL5,
DL4 and DL3 green LEDS must be on.
- after a short pause, the automation carries out one complete closure to optimize the closing
power.
WARNING:
- The procedure can be stopped by pressing the STOP button.
- During the various stages of the operation, if the sensor is activated saving is stopped.
Please remember that an obstacle during saving is interpreted as a mechanical
limit stop (the system does not start any safety operation, it just stops the motors).
Make sure you don’t stand near the automation during saving.
ENGLISH