Models 8752 & 8756 with Horizon® Pump Troubleshooting Guide
PROBLEM PROBABLE CAUSE REMEDY PAGE
REF.
12. The machine will not
operate in the AUTO
mode.
a. The machine is
unplugged.
a. Plug the machine into the
wall receptacle.
-- -- --
b. The circuit breaker is off
or the fuse is blown.
b. Turn the breaker on or
replace the fuse.
-- -- --
c. Low on mix. The “MIX
OUT light is flashing.
c. Add mix to the mix tank
and press the AUTO key.
15
d. The mix probe is not
installed properly or is
damaged.
d. Check the mix probe
installation.
29
e. The beater motor is out on
reset.
e. Reset the freezer . 15
f. The unit is off on high
head pressure.
f. Air cooled: clean the
condenser.
W ater cooled: check the
water supply.
Contact a service
technician.
36
g. The power switch is in the
OFF position.
g. Place the power switch in
the ON position and press
the AUTO key.
27