8-2
TROUBLESHOOTING GUIDE
Model C302
Troubleshooting Guide
8
9. Excessive mix leakage
from door spout.
a. Inadequate lubrication of draw
valve O-rings.
a. Lubricate properly.
6-3
b. Wrong type lubricant on draw valve
O-rings.
b. Use food grade lubricant
(example: Taylor Lube HP).
6-1
c. Worn or missing draw valve
O-rings.
c. Replace or install O-rings on draw
valve.
6-3/9-1
10. Unable to adjust brix. a. Syrup lines need to be cleaned and
sanitized.
a. Clean and sanitize syrup lines.
- - -
b. Blocked flow control. b. Contact a service technician. - - -
11. Lack of syrup being
supplied to machine.
a. Loss of CO
2
to propel syrup. a. Contact a service technician.
- - -
b. Clogged or kinked syrup lines. b. Sanitize syrup lines regularly. If
kinked, repair, or replace.
- - -
Problem Probable Cause Remedy