18
Systems, Controls and Operations
Model C602
040617
Service Menu Options
Touch the AUTO symbol or OPTIONAL FLAVOR
symbol
to move up or down through the Menu.
Select a Menu option by aligning the option with the
arrow on the left side of the screen, and then touch
the CALIBRATION symbol
. Exit the Menu
program by selecting EXIT FROM MENU or touch
the CONE symbol
.
The following menu options are listed in the Service
Menu:
Note: Options “EXIT FROM MENU” through
“CURRENT CONDITIONS” can also be accessed
through the Manager’s Menu.
EXIT FROM MENU
SYRUP CALIBRATION
VERIFY CALIBRATION
RESET DRAW COUNTER
SET CLOCK
AUTO HEAT TIME
AUTO START TIME
STANDBY MODE
BRUSH CLEAN CYCLE
MIX LEVEL AUDIBLE
FAULT DESCRIPTION
LOCKOUT HISTORY
HEAT CYCLE SUMMARY
HEAT CYCLE DATA
SYSTEM INFORMATION
CURRENT CONDITIONS
TEMPERATURE SCALE
STANDBY TEMPERATURE
HOPPER TEMPERATURE
GLYCOL T EMPERAT URE
VISCOSIT Y SETTING
COMPRESSOR CYCLE TIME
COMPRESSOR ON DELAY
BEATER OFF DELAY
MIXPUMPOFFDELAY
WHITESPOT ADJUST
CAL SYRUP TIME
DRAW SAFETY TIME
EDIT UNIT ID
CALIBRATE PROXIMITY SWITCH
SELECT LANGUAGE
ABORT HEAT CYCLE
SYRUP MOT OR SETUP
EXIT FROM MENU
Selecting “EXIT FROM MENU” will exit the Menu
and the return the control panel symbols to normal
operation.
SYRUP CALIBRATION
The SYRUP CALIBRATION option allows the
technician to access the CALIBRATION screen
selections from the Service menu. The same
functions found in the Calibration menu are
displayed on the screen when this menu option is
selected. (See Figure 25.)
UNFLAVORED DRAW
SYRUP CALIBRATION
SYRUP PRIME
> EXIT
Figure 25
Note: The Unflavored Draw option will only appear
on the screen when the shake side is in the AUTO
mode.
See Syrup Calibration on page 59 for additional
information.
VERIFY CALIBRATION
The VERIFY CALIBRATION option is used to verify
that the amount of syrup dispensed is within the
proper specification. (See Figure 26.)
VERIFY CALIBRATION
Select a flavor
<- Press to clear
Figure 26
Remove the syrup valve from the dispensing door.
With the line fully primed with syrup, position the
syrup valve over the small chamber side of the
divided syrup cup, and then select the
corresponding favor selection. Syrup will flow into
the cup for 5 seconds (7 seconds for Triple Thick
Shake Syrup) and then automatically stop flowing.
Place the cup on a flat surface and check the
amount of syrup dispensed. If the level is not within
the correct specification, the flavor will need to be
recalibrated.
Select the CALIBRATION symbol
to exit the
VERIFY CALIBRATION screen and return to the
Menu list.