20
Systems, Controls and Operations
Model C602
AUTO HEAT TIME
The AUTO HEAT TIME screen allows the manager
or service technician to set the time of day in which
the heat treatment cycle will start. (See Figure 33.)
AUTO HEAT TIME
00:00
Change
>Exit
Figure 33
Note: Do not advance the Auto Heat Time setting
except on the day the unit is brush cleaned.
Increasing the time between heat cycles will cause
the machine to soft lock if the start of the cycle does
not begin within 24 hours from the start of the
previous heat treatment cycle.
To set the AUTO HEAT TIME select the AUTO
symbol
to move the arrow to Change. Then
select the CALIBRATION symbol
. The screen
will display the time with the cursor under the hour
position. (See Figure 34.)
AUTO HEAT TIME
00:00
__
Figure 34
Select the AUTO symbol
or the OPTIONAL
FLAVOR symbol
to increase or decrease the
hour to the desired setting. Then move the cursor to
the minutes position by selecting the CALIBRATION
symbol
. Adjust the setting for minutes, then
select the CALIBRATION symbol
to save the
setting and return to the AUTO HEAT TIME screen.
Select the CALIBRATION symbol
to exit the
screen and return to the Menu.
AUTO START TIME
The AUTO START TIME option allows the manager
or service technician to set the time of day at which
the machine automatically enters the AUTO mode
from the STANDBY mode. The machine must be in
the STANDBY mode without a freezer lock condition
in order to AUTO start at the programmable time.
The AUTO START TIME can be disabled and will
require starting the AUTO mode manually. (See
Figure 35.)
AUTO START TIME
DISABLED
Enable
> Disable
Figure 35
Enable the AUTO START TIME by selecting the
AUTO symbol
to move the arrow up to Enable.
Select the CALIBRATION symbol
to advance to
the next screen. (See Figure 36.)
AUTO START TIME
00:00
Change
>Exit
Figure 36

Other manuals for Taylor C602