TROUBLESHOOTING GUIDE
8-3
Model C706
Troubleshooting Guide
8
15.Excessive pump
cylinder wear.
a. Inadequate or incorrect lubrication
of pump cylinder.
a. Follow lubrication procedures
carefully.
6-5
b. Incorrect ball crank rotation. b. Contact a Taylor service technician. - - -
16.Pitting occurring inside
the pump cylinder.
a. Cleaner was left inside the pump
cylinder.
a. After brush cleaning the pump
cylinder, allow it to air dry. Follow
disassembly procedures.
6-11
17.The ball crank of the
motor reducer is broken.
a. Pump motor rotation is incorrect. a. Contact a Taylor service technician.
- - -
18.Too much pressure in
the freezing cylinder.
a. Plugged relief hole in the inlet tube. a. Clean.
- - -
19.Not enough pressure in
the freezing cylinder.
a. Malfunctioning draw switch. a. Contact a Taylor service technician.
- - -
Problem Probable Cause Remedy