2-16
CONTROLS
Models C712/C713
Controls
2
Beater Stir Cycles
Standby
When the machine is in the Standby mode, the stir cycle
will be activated. The beater stir cycle timer counts down
2 minutes (in seconds) and then activates the beater
motor for 6 seconds. After the stir cycle, the process will
repeat itself; the timer will count down
2 minutes, and the beater will run for 6 seconds.
Hopper Temperature
The hopper temperature setpoint range is 29.5°F to 39°F
(-1.4°C to 3.9°C). In the Auto or Standby mode, the
compressor starts when the hopper temperature is above
the setpoint and stops when the hopper temperature
reaches the setpoint -2°.

Table of Contents

Other manuals for Taylor c713

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor c713 and is the answer not in the manual?

Taylor c713 Specifications

General IconGeneral
TypeSoft Serve Freezer
Number of Flavors2
Refrigeration SystemAir or Water Cooled
Separate Hopper RefrigerationYes
Indicator LightsYes
Water CooledYes
Electrical208-230V, 1PH, 50/60Hz
MotorTwo 1.5 HP
Air Cooled Minimum Clearance6" on both sides