EasyManuals Logo
Home>Taylor>Freezer>C723

Taylor C723 User Manual

Taylor C723
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
Section 7
7-1
Model C723
Operator Checklist
7
Operator Checklist
During Cleaning and Sanitizing
NOTICE! Cleaning and sanitizing schedules
are governed by your federal, state, or local regulatory
agencies and must be followed accordingly. Please see
the cleaning section of this manual for the proper
procedure to clean this machine.
Standby mode must not be used instead of proper
cleaning and sanitizing procedures and frequencies set
forth by the ruling health authority. The following
checkpoints should be stressed during the cleaning and
sanitizing operations.
IMPORTANT! Cleaning and sanitizing must be
performed daily.
Troubleshooting Bacterial Count
Thoroughly clean and sanitize the machine
regularly, including complete disassembly and
brush-cleaning.
Use all brushes supplied for thorough cleaning.
The brushes are specially designed to reach all
mix passageways.
Use the white bristle brush to clean the mix inlet
hole, which extends from the mix hopper down to
the rear of the freezing cylinder.
Use the black bristle brush to thoroughly clean the
rear shell bearing at the rear of the freezing
cylinder. Use a generous amount of cleaning
solution on the brush.
If local health codes permit the use of rerun, make
sure the mix rerun is stored in a sanitized, covered
stainless steel container and used the following
day. Do not prime the machine with rerun. When
using rerun, skim off the foam and discard. Mix
the rerun with fresh mix in a ratio of 50:50 during
the day’s operation.
On a designated day of the week, run the mix as
low as feasible and discard it after closing. This
will break the rerun cycle and reduce the
possibility of high bacteria and coliform counts.
Properly prepare the cleaning and sanitizing
solutions. Read and follow the label directions
carefully. Too strong of a solution may damage the
parts, and too weak of a solution will not do an
adequate job of cleaning or sanitizing.
The temperature of the mix in the mix hopper and
walk-in cooler should be below 40
°F (4.4°C).
Regular Maintenance Checks
Replace scraper blades that are nicked or
damaged. Before installing the dasher assembly,
make sure that the scraper blades are properly
attached to the dasher shaft.
Check the rear shell bearing for signs of wear
(excessive mix leakage in rear drip pan) and make
sure it is properly cleaned.
Using a long brush and a cloth towel, clean the
rear shell bearing and the female hex drive socket
of lubricant and mix deposits.
Dispose of O-rings and seals if they are worn,
torn, or fit too loosely, and replace them with new
ones.
Follow all lubricating procedures as outlined in
“Assembly.”
ALWAYS FOLLOW LOCAL HEALTH CODES.

Other manuals for Taylor C723

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor C723 and is the answer not in the manual?

Taylor C723 Specifications

General IconGeneral
BrandTaylor
ModelC723
CategoryFreezer
LanguageEnglish

Related product manuals