- 53 -
3. TROUBLESHOOTING GUIDE
(12)
: Accelerator signal wire short-circuited
Automatically resets when the input returns to
normal.
① Check the voltage at CN2D-8 and -9 terminals on
the drive motor inverter unit.
② Check the drive motor inverter unit (CN2D-8, -9)
harness.
Correct the wiring.
③ Check the accelerator unit.
Repair the accelerator unit.
: Accelerator potentiometer not positioned
properly
Automatically resets when the accelerator voltage
is 0.8 V or more.
① Check the voltage at the CN2D-8 and -9 terminals
on the drive motor inverter unit.
② Check the accelerator unit for proper positioning.
Accelerator voltage should be 1.00 V in the neutral
position.
③ Replace the accelerator unit.
(13)
: Drive motor inverter unit U-phase FET open
Resets when the key switch is turned OFF.
: Drive motor inverter unit V-phase FET open
Resets when the key switch is turned OFF.
: Drive motor inverter unit W-phase FET open
Resets when the key switch is turned OFF.
① Check the drive motor for loose terminals.
Retighten.
② Check the drive motor cable.
Correct the cable.
③ Replace the drive motor inverter unit.
(14)
: V-phase current detection abnormal
AD input too low, AD input too high
Resets when the key switch is turned OFF.
: V-phase current offset abnormal
AD input too low, AD input too high
Resets when the key switch is turned OFF.
: W-phase current detection abnormal
AD input too low, AD input too high
Resets when the key switch is turned OFF.
: W-phase current offset abnormal
AD input too low, AD input too high
Resets when the key switch is turned OFF.
① Replace the drive motor inverter unit.