EasyManua.ls Logo

TCM FB20-8 - Page 215

TCM FB20-8
259 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(12)
210
-
: Accelerator signal wire short-circuited
Automatically resets when the input returns to
normal.
① Check the voltage at CN2D-8 and -9 terminals on
the drive motor inverter unit.
② Check the drive motor inverter unit (CN2D-8, -9)
harness.
Correct the wiring.
③ Check the accelerator unit.
Repair the accelerator unit.
307
-
: Accelerator potentiometer not positioned
properly
Automatically resets when the accelerator voltage
is 0.8 V or more.
① Check the voltage at the CN2D-8 and -9 terminals
on the drive motor inverter unit.
② Check the accelerator unit for proper positioning.
Accelerator voltage should be 1.00 V in the neutral
position.
③ Replace the accelerator unit.
(13)
213
16
: Drive motor inverter unit U-phase FET open
Resets when the key switch is turned OFF.
214
17
: Drive motor inverter unit V-phase FET open
Resets when the key switch is turned OFF.
215
18
: Drive motor inverter unit W-phase FET open
Resets when the key switch is turned OFF.
① Check the drive motor for loose terminals.
Retighten.
② Check the drive motor cable.
Correct the cable.
③ Replace the drive motor inverter unit.
(14)
216
24
: V-phase current detection abnormal
AD input too low, AD input too high
Resets when the key switch is turned OFF.
216
25
: V-phase current offset abnormal
AD input too low, AD input too high
Resets when the key switch is turned OFF.
216
26
: W-phase current detection abnormal
AD input too low, AD input too high
Resets when the key switch is turned OFF.
216
27
: W-phase current offset abnormal
AD input too low, AD input too high
Resets when the key switch is turned OFF.
① Replace the drive motor inverter unit.

Table of Contents