EasyManuals Logo

TCS ISW3030 User Manual

TCS ISW3030
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12 07/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Configuration options
function
manually
TCSK-01
configo
TM
from version 1.3.3
ring tone volume
x
-
voice volume
x
-
selecting ring tones for door calls,
internal calls and floor calls
x
x
ring tone for door call 2
x
parallel allocation
x
x
change audio AS border
x
block ring tone output
x
block ring tone selection
x
reset to factory settings
x
Programming with the Service Device TCSK-01
The indoor station is acting like a device for manually controlled duplex communication.
Use the commands „8“ for configuring (see product information Service Device TCSK-
01).
Ser. no. = the serial number of the new indoor station that should be configured
ParSNo. = the serial number of the indoor station, to which the new configured indoor station is allocated
General information on the conduit in TCS audio systems
The conduit is determined by structural conditions and is only limited by its length
.
Note when choosing the cables: the loop re-
sistance can amount max. 20 Ω (table)
In compliance to the max. permitted loop re-
sistance the wire cross-section can be doubled,
that means, that for one wire two lines can be
used (illustration). The lines have to be twisted.
In case of using shielded cables: connect the
shielding with each other and put i tone-sided on
mass (b-wire) in the power supply
Optional strand or star formed wiring