16 44 1705 001GB-H FMT 3 meter
3.5 Instructions for installing FMT 3 on HORNET W 85 H
Before installation, check all components to ensure that all packaging materials have been
completely removed.
Insert sealing rings (2) into adapter coupling (4) on both sides.
Screw adapter coupling (4) with sealing rings (2) onto the meter (3) and screw tightly in place.
You do not have to pay attention to the direction of flow, as the FMT 3 can be used with both
flow directions.
Place O-ring on pressure port and lubricate. Lightly insert meter (3) onto pressure port where
the cap nut (1) is. Now screw the cap nut (1) onto the meter (3) and screw tightly in place. When
doing so, ensure that the smaller of the two diameters on the meter connects to the pressure
port in order to correctly secure the O-ring in place.
After assembly, check all connections for leaks.