18 44 1705 001GB-H FMT 3 meter
3.6 Instructions for installing FMT 3 on HORNET W 85 H INOX
• Before installation, check all components to ensure that all packaging materials have been
completely removed.
• Insert sealing ring (2) into the adapter on pressure side (1).
• Insert sealing ring (2) into the hose connector (4).
• Screw hose connector (4) with sealing ring (2) onto the meter (3) and screw tightly in place. You
do not have to pay attention to the direction of flow of the meter, as the FMT 3 can be used
with both flow directions.
• Screw meter (3) with sealing ring (2) into the adapter on the pressure side (1) and screw tightly
in place.
• After assembly, check all connections for leaks.