13
4.3.1
Fire‐up/Damping
Oncethisfunctionhasbeenselected,thefire‐upprocessstarts.
Theuserisaskedtoconfirmthefire‐upprocessactivation.
Thenextstagesoffire‐upprocessaredescribedinsection:
Błąd!Niemożnaodnaleźćźródłaodwołania.Fire‐up,page:
10
Itisadependentfeature‐itdependsontheoperationmode.Fire‐
upfunctionisdifferentoperationmodesisdescribedinthefollowingsection:
4.4.12Ecomode,page:39
Oncethefire‐upprocesshasbeenactivatedinthecontrollermenu,thisoptionchangesintoDamping,which
enablestheusertostartCHboilerdampingprocess.
4.3.2
Fueltankfull
Thisfunctionshouldbeusedafterthefueltankhasbeenfullyfilled,inordertoresetthefuellevelto100%.
NOTE
Beforeusingthisfunctionforthefirsttimeitisnecessarytocalibratethefuelfeederoperation.
4.4.10Fuellevelcalibration,page:38
4.3.3
Temperaturesettings
MAINMENU
TEMPERATURESETTINGS
Pre‐setCHtemperature
Pre‐setDHWtemperature
CHboilerhysteresis
DHWhysteresis
Pumpswitchontemperature
Pre‐setroomtemperature*
*Whenroomregulatorisconnected,withRScommunication
Afterselectingagivenicon,thedisplayshowsapanelenablingtheusertochangethesettingusinga
sliderorarrows.
Pre‐setCHtemperature
Thisoptionisusedtodefinethepre‐settemperatureoftheCHboiler.Thesettingrangeavailableis55°C‐80°C
(thesettingrangemaybechangedbythemanufacturerorfitterintheservicemenu).
Pre‐setDHWtemperature
Thisfunctionisusedtodefinethepre‐settemperatureofthedomesticwater.After thewaterin thetank
reachesthis temperature,DHWpump isdisabled. Thepumpwillbe enabledagainwhen thetemperature
dropsbelowthepre‐settemperatureminusthevalueofDHWhysteresis(readfromtheDHWsensor).DHW
temperaturerange:40°C‐60°C.