Inthiswaythefueltankiscalibratedandthecontrollerwillautomaticallyinformtheuseraboutthecurrent
fuellevel.Suchcalibrationisusuallyperformedonlyonce.Whenthefueltankisfilledagain,itisenoughto
selecttheoptionFueltankfullintheuser’smenu.
Afterafuellevelpanelisselectedinthemainscreen,thedisplayshowstheestimatedamountoffuelleft(%)
andtheexpectedtimeneededforthefueltobeusedup(daysandhours).
4.4.11
Cleaning
FITTER'SMENU
CLEANING
Cleaningperiod
Grate‐damping*
Grate‐operationmode*
Grate‐pauseinoperation*
*Thisparameterisdisplayedonlyafterthegratehasbeenactivatedintheservicemenu.
Cleaningperiod
Thisparameterisusedtodefinethefrequencyofgratecleaningactivation.Thecleaningprocedureinvolves
dampingtheCHboilerandfire‐up.Ifthetimeissetat0,thecleaningprocesswillbedisabled.
Grate‐damping
Thisfunctionisusedtoactivatethegrateafterdamping.Theoperationtimemaybe configuredinservice
menu.Whenthetimeisover,thegraterelaywillbedisconnected.
Grate‐operationmode
This function is used to configure grate operation in operationmode.Thegrateisactivatedperiodically
accordingtoGrate‐pauseinoperationsettings.
Grate‐pauseinoperation
Thisparameterdefinesthetimeleftbeforegrateactivationinoperationmode.ItisdisplayedwhenGrate‐
operationmodeisactive.
4.4.12
Ecomode
FITTER'S
MENU
TRYBECO
OFF
ON
TheusermaydecideifEcomodeshouldbeactiveornot.Fire‐upprocessdependsontheselectedoperation
mode: