Househeating
Withoutroomregulatorandbuffer(Fire‐upfunction):
Thisoptionshouldnotbeselectedbecauseinsuchacaseitwillremaininactive.
RoomregulatorON,withoutbuffer(Fire‐upfunction+Roomregulator):
Whenthefire‐upfunctionisselected,theroomregulatorcontrolstheCHboileroperation.Whenthepre‐set
roomtemperatureisreached,theCHboilerisdisabled.Itwillbeenabledagainwhentheroomtemperature
dropsbythepre‐sethysteresisvalue.Whenthisfunctionisinactive,theCHboileroperatesaccordingtopre‐
configuredoperationparameters.
BufferON(Fire‐upfunction+Buffer+DHWfunctionfromCHboilerorbuffer):
Whenthefire‐upfunctionisselected,thebuffercontrolstheCHboileroperation.Whenthepre‐setbuffer
temperature is reached,the CH boiler is disabled. When this function is inactive, the CH boiler operates
accordingtopre‐configuredoperationparameters(dampingandfire‐upbasedonCHsensor).DHWfunction
servesnoroleinthiscase,butitshouldbeselecteddependingonthetypeofheatinginstallation.
Watertankpriority
Withoutroomregulatorandbuffer(Fire‐upfunction):
Thisoptionshouldnotbeselectedbecauseinsuchacaseitwillremaininactive.
RoomregulatorON,withoutbuffer(Fire‐upfunction+Roomregulator):
TheCHboilerisdampedwhenthepre‐setDHWtemperatureisreachedandtheroomregulatorinformsthat
thepre‐setroomtemperaturehasbeenreached.EmergencyCHboilerdampingwillbecarriedoutwhenthe
pre‐setCHtemperatureisexceededby5°C.
BufferON(Fire‐upfunction+Buffer+DHWfunctionfrombuffer):
Whenthepresettemperatureofbufferbottomisreached(C2sensor), CH boiler damping will start
regardless of CH and DHW temperature. The main screen displays ‘Buffer pre‐set temperature reached’
belowFire‐up/Dampingtouchbuttons.Emergencydampingwillalsostartwhenthepre‐setCHtemperature
isexceededby5°C.
BufferON(Fire‐upfunction+Buffer+DHWfunctionfromfromCHboiler):
Whenthepresettemperatureofbufferbottomisreached(C2sensor)aswellasthepresetwatertank
temperatureisreached,CHboilerdampingwillstartregardlessofCHtemperature.Themainscreendisplays
‘Bufferpre‐settemperaturereachedandPre‐setDHWtemperaturereached’belowFire‐up/Dampingtouch
buttons.Emergencydampingwillalsostartwhenthepre‐setCHtemperatureisexceededby5°C.
Parallelpumps
Withoutroomregulatorandbuffer(Fire‐upfunction):
Thisoptionshouldnotbeselectedbecauseinsuchacaseitwillremaininactive.
RoomregulatorON,withoutbuffer(Fire‐upfunction+Roomregulator):
TheCHboilerisdampedwhenthepre‐setDHWtemperatureisreachedandtheroomregulatorinformsthat
thepre‐setroomtemperaturehasbeenreached.EmergencyCHboilerdampingwillbecarriedoutwhenthe
pre‐setCHtemperatureisexceededby5°C.
BufferON(Fire‐upfunction+Buffer+DHWfunctionfrombuffer):
Whenthepresettemperatureofbufferbottomisreached(C2sensor), CH boiler damping will start
regardless of CH and DHW temperature. The main screen displays ‘Buffer pre‐set temperature reached’
belowFire‐up/Dampingtouchbuttons.Emergencydampingwillalsostartwhenthepre‐setCHtemperature
isexceededby5°C.
BufferON(Fire‐upfunction+Buffer+DHWfunctionfromCHboiler):
Whenthepresettemperatureofbufferbottomisreached(C2sensor)aswellasthepresetwatertank
temperatureisreached,CHboilerdampingwillstartregardlessofCHtemperature.Themainscreendisplays
‘Bufferpre‐settemperaturereachedandPre‐setDHWtemperaturereached’belowFire‐up/Dampingtouch
buttons.Emergencydampingwillalsostartwhenthepre‐setCHtemperatureisexceededby5°C.