37
Oncethisoptionhasbeenselected,theadditionaldevicewillserveasfloorpump.Pozaznaczeniutejopcji
urządzeniedodatkowebędziepełnićfunkcjępompypodłogowej‐służącejdosterowaniapompąobsługującą
instalacjepodłogową.
Thefollowingparametersareusedtoconfigureitsoperation:
Roomregulator
Thisoptionisusedtoselecttheregulatorwhichwillinformifthepre‐settemperaturehasbeenreached.
Oncethepre‐settemperaturehasbeenreached,thepumpwillbedisabled.
Temperaturethreshold
Thisparameterdefinesthetemperatureoffloorpumpactivation.ItisthetemperaturemeasuredattheCH
boiler.
Maximumtemperature
Thisparameterisusedtodefinethepumpdeactivationtemperature.
Sensor1selection
Thisoption isusedto selectwhich temperature sensorshould beused to providedata forcontrollingthe
operationofthedeviceconnectedtotheadditionalcontact–theheatsource(activationthreshold).
Sensor2selection2
Thisoption isusedto selectwhich temperature sensorshould beused to providedata forcontrollingthe
operationofthedeviceconnectedtotheadditionalcontact–(pre‐settemperature).
Alarm
Iftheuserhasanalarminstalledathome,afterselectingthisoptionandconnectingittotheadditional
contactofthecontroller,itcansynchronizewiththealarmsoccurringinthedevice.
Example:
Iftheuserhasanalarminstalled,withsoundsignalinsidethebuilding,thesoundsignalwillbe
activatedifanyalarmoccursinthecontrollere.g.fire‐upfailure.
Remoteoperation
Oncethisoptionhasbeenactivated,theusermaycontroltheadditionalcontactviaInternetwebsite.
4.4.9
Roomregulator
FITTER'SMENU
ROOMREGULATOR
RegulatorTECHRS
Regulatorstandard
CHpumproomregulator
Roomreg.temp.lower
Thisfunctionenablestheusertoconfiguretheoperationparametersoftheroomregulatorconnectedtothe
pellet‐firedboilercontroller.Itisnecessarytoactivatethecooperationwiththeroomregulatorafterithas
beenconnected,byselectinganappropriatetypeofroomregulator.Itispossibletoconnectuptotworoom
regulatorstothecontroller.