15
Automaticoperation
MAINMENU
AUTOMATICOPERATION
Weighingfuel2minutes
Fuelweight
Calorificvalue
Fanmax.
Fanmin.
Weighingfuel2minutes
Thisfunction enablesthe userto checkthe weightofthefuel fed bythe feederwithin2 minutes.Before
activating this function, it is necessary to disconnect the feeder from the burner and provide a suitable
container.Next,waituntilthefeedingprocessfinishesandweighthefuel.
Fuelweight
Entertheweightofthefuelfedwithin2minutes.
Calorificvalue
Enterthecalorificvalueofpelletfuel(givenonthepackaging).
Fanmax.
Thisoptionisusedtodefinethefanspeeduntilthepre‐settemperatureisreached.
Fanmin.
This option is used to define the fan speed in sustain mode, i.e.afterthepre‐settemperaturehasbeen
reached.
zPIDoperation
MAIN
MENU
zPID
Feedercoefficient
Fancoefficient
Feedercoefficient
Feedercoefficientservestooptimizethefeederoperationsothatitsuppliesanappropriateamountoffuel.
UsingthisfunctiontheusermayincreaseordecreasetheamountoffuelfedtotheCHboiler.
Fancoefficient
Thisfunctionisusedtoadjustthefanspeed.Iftheblowforce is too low/high, the coefficient should be
adequatelyincreased/decreasedinordertoensureefficiency.