15
Automaticoperation
MAINMENU
AUTOMATICOPERATION
Weighingfuel2minutes
Fuelweight
Calorificvalue
Fanmax.
Fanmin.
Weighingfuel2minutes
Thisfunction enablesthe userto checkthe weightofthefuel fed bythe feederwithin2 minutes.Before
activating this function, it is necessary to disconnect the feeder from the burner and provide a suitable
container.Next,waituntilthefeedingprocessfinishesandweighthefuel.
Fuelweight
Entertheweightofthefuelfedwithin2minutes.
Calorificvalue
Enterthecalorificvalueofpelletfuel(givenonthepackaging).
Fanmax.
Thisoptionisusedtodefinethefanspeeduntilthepre‐settemperatureisreached.
Fanmin.
This option is used to define the fan speed in sustain mode, i.e.afterthepresettemperaturehasbeen
reached.
zPIDoperation
MAIN
MENU
zPID
Feedercoefficient
Fancoefficient
Feedercoefficient
Feedercoefficientservestooptimizethefeederoperationsothatitsuppliesanappropriateamountoffuel.
UsingthisfunctiontheusermayincreaseordecreasetheamountoffuelfedtotheCHboiler.
Fancoefficient
Thisfunctionisusedtoadjustthefanspeed.Iftheblowforce is too low/high, the coefficient should be
adequatelyincreased/decreasedinordertoensureefficiency.
