7 To Supply Power Source
TOP PREVIOUS NEXT
This unit SA-EH560 is designed to operate on power supplied form system connected./For system
connection, refer to Fig. 7-1.
Fig. 7-1.
When the unit SA-EH560 has to test and service alone, use the following method to supply power
source.
1. Short the section between W902A Pin 3 and C740 (-) (GND). (Refer to
Fig. 7-2. )
2. Connect this unit to an AC power supply cord./(This unit come to stand-by mode.)
3. Turn the unit ON.
Fig. 7-2.