4. Confirm that the reading of the laser power meter or cartridge type laser power
meter is within the specified. If it is not within the specified range, adjust by
turning VR1. (Refer to
Fig.12.)
Specified range (read power): 600
µ
µµ
µ
W or lower
Fig.12
24