HF
signal
turned
into
SRF
signal?
1
FO
error
amp.
failure:
*1C6501,6504
@
DSL
circuit
failure:
Focus
servo
locked?
¢
1C501
SRF
signal
check
method
Verify
that
the
SRF
signal
is
present
at
2
of
IC501
1:
Microprocessor
failure:
°1C401
‘2
Control
system
failure:
©
1C6501,6504
3:
TR
error
amp.
failure:
_
*1C6501,6503,6504
‘4
Pickup
failure:
¢
Radial
coil
SRF
signal
synchronized
with
PCK?
1)
PLL
circuit
failure:
¢
10301,
1C501
Radial
servo
locked?
Synchronization
check
method
Trigger
the
oscilloscope
with
the
RF
signal(TJ306)and
observe
the
PCK
at
Yes
;
TJ303.
If
phase
synchronization
is
establish-
ed,
the
FPC
at
IC301’s
pin
43
will
be
regulated
to
approx.
2.6V.
No]
4:
CLV
circuit
failure:
©
1C301
CLV
servo
entered
the
Phase
Compare
mode?
1
AGC
circuit
failure:(RF
Amp.)
°1C6501
AGC
circuit
check
method
Verify
that
HF
signal
amplitude
at
|
TJ306
is
1.0V
p-p
~
1.4Vp-p.
HF(RF)
Signal
present?
EFM
signal
and
PCK
clock
outputs
present?
NO}
1
PLL
circuit
failure:
©
10102
EFM
and
PCK
check
method
Check
the
waveform
of
EFM
at
IC
501
pin
5
and
that
of
PCK
at
IC501
pin
3.
Yes
1:
DF/DAC
circuit
failure:
¢
iC801
‘2;
Low-pass
filter
circuit
failure:
*
1C803,802.
¢
1C805,806
Audio
signal
output
present?
Play
operation
Printed