EasyManua.ls Logo

TechniSat Switch Series

TechniSat Switch Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
8 Basic command class
Members of association group 2 are controlled with Basic_Set commands of
the basic command class.
If the TechniSat series switch is switched on, a Basic_Set (0 x FF) command
is sent to members of association group 2.
If the TechniSat series switch is switched o, a Basic_Set (0 x 00)
command is sent to members of association group 2.
9 Notification command class
Notification Event Description
Power management
(0 x 08)
Inactive (0 x 00) No event detected / event
cancelled
Overload detected
(0 x 08)
The maximum permissible
load on L1 / L2 was
exceeded
10 Supported Z-Wave command classes
Main device:
Command class Version Required Z-Wave safety
levels
Association 2 highest permied
Association group information 1 highest permied