8 Basic command class
Members of association group 2 are controlled with Basic_Set commands of
the basic command class.
If the TechniSat series switch is switched on, a Basic_Set (0 x FF) command
is sent to members of association group 2.
If the TechniSat series switch is switched o, a Basic_Set (0 x 00)
command is sent to members of association group 2.
9 Notification command class
Notification Event Description
Power management
(0 x 08)
Inactive (0 x 00) No event detected / event
cancelled
Overload detected
(0 x 08)
The maximum permissible
load on L1 / L2 was
exceeded
10 Supported Z-Wave command classes
Main device:
Command class Version Required Z-Wave safety
levels
Association 2 highest permied
Association group information 1 highest permied