FLEXability LINE: Service & Maintenance Manual - rev. 1.0
Page 6.12
Figure 6.7-4
6. Bent a little bit the plastic support indicated
by the arrow and pull out the plate e, paying
attention to the rollers f, which are driving
the graduated tape.
During the reassembly procedure, pay
attention to pass correctly the tape on
the rollers.
7. Remove the tape and its winding g from the
plastic support.
Before to reassemble the tape winding,
preload it with 3 turns.
Figure 6.7-5
8. Back off the 4 screws h using a 3mm hex
wrench and remove the carriage left side
casing.
Figure 6.7-6
9. Tilt the machine on the right side.
10. Back off the nut i using a 13mm wrench and
a 4mm hex wrench.
11. Disconnect the cable, indicated by the arrow,
of the encoder device which shows the
carriage position, fixing it to avoid that it will
be swallowed into the frame by the encoder
device spring.
12. Remove the cable/tape from the machine
frame.
Continued on following page

Table of Contents