TRAÇABILITÉ CRÉATIVE
CREATIVE TRACEABILITY
www.technomark-marking.com
Modèle du 06/11/2015
TECHNOMARK
3 Allée Michaël FARADAY
Parc d’activités STELYTEC
42400 SAINT-CHAMOND (France)
Tel : +33 (0) 4 77 22 25 91
Fax : + 33 (0) 4 77 22 38 93
E-mail : info@technomark-marking.com
4.11. Disable Answer - G
Answer codes can be disabled using the G command into the frame.
Example: Open the file TEST with no error code return:
[STX]G[CR]ATEST[CR][ETX]
4.12. Save File S
The save of the current file can be done by sending the command S :
[STX]SXXX…XXX[CR][ETX]
Where XXX…XXX is the file name.
Example : save the file named TEST:
[STX]STEST[CR][ETX]
4.13. Create a variable V
Creating a variable in the current file can be realized by sending the command V :
[STX]VLLMFNN..NN[CR][ETX]
The parameters are the following (Erreur ! Source du renvoi introuvable. Add a variable):
LL : variable length on 2 characters
M : modifiable 0 for no, 1 pour yes
F : forced 0 for no, 1 for yes
NN..NN : variable name from 1 to 8 characters
Example : Create a variable VAR with a length of 10, modifiable and non forced
[STX]V1010VAR[CR][ETX]
4.14. Origin return - O
The origin return can be done by sending the command O :
[STX]O[CR][ETX]