EasyManua.ls Logo

Technomark M4 inline - 16 Channels State Display; Dashboard Indicators

Technomark M4 inline
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 7 sur 26
TRAÇABILITÉ CRÉATIVE
CREATIVE TRACEABILITY
www.technomark-marking.com
Modèle du 06/11/2015
TECHNOMARK
3 Allée Michaël FARADAY
Parc d’activités STELYTEC
42400 SAINT-CHAMOND (France)
Tel : +33 (0) 4 77 22 25 91
Fax : + 33 (0) 4 77 22 38 93
E-mail : info@technomark-marking.com
4.3.Serial Number command - C
It is possible to give a value to a serial number with command C followed by the serial number name, then the
character = then the desired value.
Example:give the value 123 to a serial number NUM
[STX]CNUM=123[CR][ETX]
4.4.Marking parameters command - H
Command H allows to setup marking parameters of the current file on the control box.
The parameters values are :
M : mirror mode m. ‘0’ no mirror, ‘1’ horizontal mirror, ‘2’ vertical mirror
Z : Zero appearance. ‘0’ for crossed zero, ‘1’ non crossed zero
V : marking speed. From ‘1’ to ‘5’
A : '0'
DDDD : '0000’
ZZZZ : ‘0000’
ZZZZ : ‘0000’
The frame has the following form:
[STX]HMZVADDDDZZZZZZZZ [CR][ETX]
Example: No mirror mode, slashed zero, speed 2:
[STX]H0020000000000000[CR][ETX]
Example: No mirror mode, with slashed zero, speed 5 :
[STX]H0052000000000000[CR][ETX]
4.5.IDI command - I
To set IDI file parameters, send the I command with IDI parameters.
Value 0 to disable IDI, 1 to enable IDI flat mode and 2 to enable curved mode.
Example: IDI flat mode for the current file:
[STX]I1[CR][ETX]