8.3 INFORMATION REGARDING THE MODE OF OPERATION
FIGURE 16: Do not rip
Do not operate the hydraulic breaker for more than 30 seconds at the same point without the
tool penetrating. It can lead to overheating and damage the tool tip. Search for a suitable
point where the tool can penetrate, e.g. a weak spot in the material.
Do not rotate the support frame such that you take support of the tip.
Keep the hydraulic breaker in a perpendicular position for at least one minute after every working
hour if the hydraulic breaker has been operated in a horizontal position or upside-down position.
This allows stones to come out from the bush for instance.