6. If the power supply cable is damaged, it must be substituted by the manufacturer or by its
technical assistance service or however by a person with similar qualications, so as to avoid
all risks. No liability whatsoever can be accepted if the above instructions in not complied with.
7. In order to prevent any risks if the the compressor supplied is damaged, these must be replaced
by qualied technician.Installation must be carried out only by qualied technicians according to the
regulation in force. No liability whatsoever can be accepted if the above instructions in not complied with.
WARNING
Any operation of ordinary and extraordinary maintenance of the equipment must be done disconnecting
the electric power supply. This maintenance must be done by qualied technician.
The plug has to be always connected to a xed outlet. It is strictly forbidden to connect the equipment
plug to an extension cord or an adapter.
2.2 STARTING THE BLAST CHILLER
ATTENTION
The rst start up must be carried out by qualied staff.
Before switching on the blast chiller, be sure that:
Your hands must be dry.
The surface of the blast chiller must be dry.
The oor and the electrical socket must be dry.
Furthermore, be sure that:
The build in condensing unit blast chiller must be carried only in upright position. If it had leaned, we
recommend to wait at least 8 hours before proceeding with the start so that the oil will ow in all the
components, lubricating them again.
For the temperature setting make reference to the corresponding chart about product categories/ usage tem-
perature, in addition For the working parameters regulation refer to the user instructions of the control panel
enclosed to this current manual.
Once the blast chiller is connected with the power cable (see the previous paragraph), proceed
powering it with the switch closing.
For the built in unit, before plugging it in, verify that the selector is open in 0, OFF or green position. Insert the
socket and then turn off the switch. Before placing inside the food to be chilled or frozen, it is necessary to clean
the chamber of the appliance (see chapter about cleaning) and afterwards it will be required to chill in advance
the chamber before starting the positive or negative processes.
For regulating the functioning parameters consult the instructions for the instrument panel enclosed to the
current manual.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tecnodom Attila Series and is the answer not in the manual?

Tecnodom Attila Series Specifications

General IconGeneral
BrandTecnodom
ModelAttila Series
CategoryChiller
LanguageEnglish

Related product manuals