2.4.1 PERIODIC MAINTENANCE
Periodic inspection will minimize machine downtime and increase operating efficiency.
FOR THE OPERATOR / FOR THE TECHNICAL SERVICE
GREASING SCREW WITHOUT END
− Turn the tank completely
− Connect a grease fitting to the connection on the lower front on the right side.
− Use the grease nipple 3/4 times.
− Move the tank to an intermediate position
− Use the grease nipple 2/3 times.
− Move the tank (cycle completely overturned and in a horizontal position) 2/3 times.
It is advisable to carry out this operation every three months, or whenever the overturn is tiring or noisy.
FOR THE TECHNICAL SERVICE
At each intervention:
− Close all the panels carefully.
− Keep the inside of the sides, where the components are present, clean and dry.
− Keep wiring and electrical connections in good condition.
CHECKS / ANNUAL INTERVENTIONS
1) Greaseing of the tilting rod bearing.
− Remove the front panel of the machine.
− Connect a grease fitting to the bearing located behind the wall from which the tilt rod comes out.
− Use the grease nipple 2/3 times.
2) Check the panels coupling, they must be perfectly closed with all screws.
3) Check water supply seal (water filling tap).
4) Verification closing terminals of electrical parts connections. Cleaning of electrical parts.