4-9 
Function 
Code No. 
Description Range/Code 
Factory 
Setting 
Remarks
04-03 
Momentary Power Loss and 
Restart 
0 : Momentary Power Loss and Restart 
disable 
1 : Momentary power loss and restart 
enable 
2 : Momentary power loss and restart 
enable while CPU is operating. 
(According to the capacity of DC 
power) 
0  
04-04 
Momentary Power Loss 
Ride-Thru Time (Seconds) 
0.0 - 2.0  0.5   
04-05 Auto Restart Method 
0 :
 Enable Speed Search 
1 : Normal Start 
0  
04-06  Auto Restart Delay Time (Seconds)  0.0 - 800.0  0.0   
04-07  Number of Auto Restart Attempts  0-10  0   
04-08  Reset Mode Setting 
0 : Enable Reset Only when Run 
Command is Off 
1 :
 Enable Reset when Run   
Command is On or Off 
0  
04-09  Direct Running After Power Up 
0 :
 Enable Direct running after power 
up 
1 :
 Disable Direct running after power 
up 
1  
04-10  Delay-ON Timer (Seconds)  1.8 ~300.0  1.0   
04-11 
Kinetic Energy   
Back-up Deceleration Time 
0.0 :
 Disable 
0.1~25.0:KEB Deceleration Time 
0.0  
04-12  Lower Limit of Power Voltage Detect 150.0~210.0/300.0~420.0  190.0/380.0   
04-13 
DC Injection Brake Level (%)@start
0.0~150.0 50.0  
04-14 
DC Injection Brake Time 
(Seconds) @start 
0.0~25.5 0.5 
 
04-15 
DC Injection Brake Start 
Frequency (Hz) @stopped 
0.10~10.00 1.50 
 
04-16 
DC Injection Brake 
Level(%)@Stopped 
0.0~150.0 50.0 
 
04-17 
DC Injection Brake Time 
(Seconds) @stopped 
0.0~25.5 0.5 
 
04-18  Braking transistor action level 
200V : 320~400 
380V : 550~800 
200V : 380 
380V : 690