4-16
Function
Code No.
Description Range/Code
Factory
Setting
Remarks
13-07
Auto _ Run Mode
Frequency Command 7
13-08~
13-15
Reserved Reserved
13-16
Auto_ Run Mode Running
Time Setting 0
0.0 ~ 3600.0 (second)
0.0
13-17
Auto_ Run Mode Running
Time Setting 1
13-18
Auto_ Run Mode Running
Time Setting 2
13-19
Auto_ Run Mode Running
Time Setting 3
13-20
Auto_ Run Mode Running
Time Setting 4
13-21
Auto_ Run Mode Running
Time Setting 5
13-22
Auto_ Run Mode Running
Time Setting 6
13-23
Auto_ Run Mode Running
Time Setting 7
13-23~
13-31
Reserved Reserved
13-32
Auto_ Run Mode Running
Direction 0
0: stop
1: forward
2: reverse
0
13-33
Auto_ Run Mode Running
Direction 1
13-34
Auto_ Run Mode Running
Direction 2
13-35
Auto_ Run Mode Running
Direction 3
13-36
Auto_ Run Mode Running
Direction 4
13-37
Auto_ Run Mode Running
Direction 5
13-38
Auto_ Run Mode Running
Direction 6
13-39
Auto_ Run Mode Running
Direction 7
Notes : *1 Can be modified during run
*2 cannot be modified while communication is active
*3 do not change while making factory setting
*4 the parameter will be changed by replacing model
*5 only available in V/F mode