TECO F510 series - 3.3.2 Wiring Peripheral Power Devices

TECO F510 series
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
33
Group 11: Auxiliary Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
11-25
~
11-27
Reserved
11-28
Frequency
Gain of
Overvoltage
Prevention 2
1~200 100
Note4
11-29
Auto De-
rating
Selection
0: Disable
0
1: Enable
11-30
Variable
Carrier
Frequency
Max. Limit
2~16 KVA
*a
11-31
Variable
Carrier
Frequency
Min. Limit
1~16 KVA
*a
11-32
Variable
Carrier
Frequency
Proportional
Gain
00~99 00
11-33
Rise
Amount of
DC Voltage
Filter
0.1~10.0 0.1
Note4
*1
11-34
Fall Amount
of DC
Voltage
Filter
0.1~10.0 5.0
Note4
*1
11-35
Dead band
Level of DC
Voltage
Filter
0.0~99.0 10.0
Note4
*1
11-36
Frequency
Gain of OV
Prevention
0.000~1.000 0.050
Note2
*1
11-37
Frequency
Limit of OV
Prevention
0.00~599.00
(Note8)
5.00
Note2
11-38
Deceleration
Start Voltage
of OV
Prevention
200V: 200~400V
400V: 400~800V
200V:
300
400V:
700
Note2
11-39
Deceleration
Stop Voltage
of OV
Prevention
200V: 300~400V
400V: 600~800V
220V:
350
440V:
750
Note2
11-40
OV
Prevention
Selection
0: Disable
1: OV
Prevention
Mode 1
2: OV
Prevention
Mode 2
3: OV
Prevention
Mode 3
0
Note2
11-41
Reference
Frequency
0: Deceleration
to Stop when
Reference
0
Group 11: Auxiliary Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
Loss
Detection
Frequency
Disappears
1: Operation is
Set by 11-42
when Reference
Frequency
Disappears
11-42
Reference
Frequency
Loss Level
0.0~100.0 80.0
11-43
Hold
Frequency
at Start
0.0~599.00
(Note8)
0.0
11-44
Frequency
Hold Time
at Start
0.0~10.0 0.0
11-45
Hold
Frequency
at Stop
0.0~599.00
(Note8)
0.0
11-46
Frequency
Hold Time
at Stop
0.0~10.0 0.0
11-47
EB
Deceleratio
n Time
0.0~25.5 0.0 *1
11-48
KEB
Detection
Level
200V: 190~210
200
400V: 380~420
400
11-49
11-50
Reserved
11-51
Braking
Selection of
Zero Speed
0: Disable
0
1: Enable
11-52
11-53
Reserved
11-54
Initialization
of
Cumulative
Energy
0: Do not Clear
Cumulative
Energy
0 *1
1: Clear
Cumulative
Energy
11-55
STOP Key
Selection
0: Stop Key is
Disabled when
the Operation
Command is not
Provided by
Keypad.
1
1: Stop Key is
Enabled when
the Operation
Command is not
Provided by
Keypad.
11-56
UP/DOWN
Selection
0: When
UP/DOWN in
Keypad is
Disabled, it will
be Enabled if
Press ENTER
after Frequency
Modification
0
1: When
UP/DOWN in

Other manuals for TECO F510 series

Related product manuals