34
Group 11: Auxiliary Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
Keypad is
Enabled, it will
be Enabled after
Frequency
Modification
11-57 Reserved
11-58
Record
Reference
Frequency
0: Disable
0 *1
1: Enable
11-59
Gain of
Preventing
Oscillation
0.00~2.50 0.01 *7
11-60
Upper Limit
of Preventing
Oscillation
0~100 30 *7
11-61
Time
Parameter of
Preventing
Oscillation
0~100 0 *7
11-62
Prevention of
Oscillation
Selection
0: Mode 1
1: Mode 2
2: Mode 3
1 *7
11-63
Flux-
Strengtheni
ng Selection
0: Disable
1
Note1
1: Enable
11-64
A
cceleration
Speed Gain
Adjustment
0.1~10.0 1.0
Note3
11-65
Target Main
Circuit
Voltage
200V: 200V~400V
370
Note3
400V: 400V~800V
740
11-66
2 Phase/ 3
Phase PWM
Switch
Frequency
6.00~60.00 20
Note3
11-67
Detection
Range at
Soft PWM
Function 2
0~12000 0
Note3
11-68
Detecting
Start
Frequency at
Soft PWM
Function 2
6.00~60.00 20
Note3
11-69
Gain of
Preventing
Oscillation 3
0.00~200.00 5.00
Note2
11-70
Upper Limit
of
Preventing
Oscillation 3
0.01~100.00 5.00
Note2
11-71
Time
Parameter of
Preventing
Oscillation 3
0~30000 100
Note2
11-72
Switch
Frequency 1
for
Preventing of
Oscillation
Gain
0.01~300.00 30.00
Note2
11-73
Switch
Frequency 2
0.01~300.00 50.00
Note2
Group 11: Auxiliary Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
for
Preventing of
Oscillation
Gain
*a: KVA means the default value of this
parameter will be changed by different
capacities of inverter.
*b: Default value is 1 only for V/F mode.
Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
12-00
Display
Screen
Selection
(LED)
00000~77777
From the leftmost
bit, it displays the
screen when
press DSP key in
order.
0: No display
1: Output Current
2: Output Voltage
3: DC Bus
Voltage
4: Heatsink
Temperature
5: PID Feedback
6: AI1 Value
7: AI2 Value
00321
*1
*5
12-01
PID
Feedback
Display
Mode (LED)
0: Display the
Feedback Value
by Integer (xxx)
0 *5
1: Display the
Feedback Value
by the Value
with First
Decimal Place
(xx.x)
2: Display the
Feedback Value
by the Value
with Second
Decimal Place
(x.xx)
12-02
PID
Feedback
Display Unit
Setting
(LED)
0: xxxxx (no
unit)
0 *5
1: xxxPb
(pressure)
2: xxxFL (flow)
12-03
Line Speed
Display
(LED)
0~60000
1500/
1800
*5
12-04
Line Speed
Display
Mode (LED)
0: Display
Inverter Output
Frequency
0
*1
*5
1: Line Speed
Display at
Integer.(xxxxx)
2: Line Speed
Display at One
Decimal Place.
(xxxx.x)
3: Line Speed

Other manuals for TECO F510 series