42
Communication
Address
Parameter Name & Function Default Unit
Setting
Range
Control
Mode
RS232 RS485
Torque command smooth accel/decel time
Constant
Tn110
Set Tn101=2 to enable this function.
Set the time period to rise to 63.2% of the full torque.
Torque
Command (%)
Time (ms)
Tn110
10
0
50
Torque Command
63.2
1 msec
1
10000
T 520H 010AH