31
Lab
Description
Values
Level
d2P
Second digital input polarity cL Pr2
did
Time delay for digital input alarm 5 Pr2
oA1
First configurable relay function tMr Pr2
oA2
Second configurable relay function ALL Pr2
oA3
Third configurable relay function Lig Pr2
2CH
Compressor setting during the holding C1 Pr2
OAt
Second compressor switching on delay
3
Pr2
OAS
Set point for second compressor
0
Pr2
OAH
Differential for second compressor
2.0
Pr2
OAi
Probe selection for second compressor
rP
Pr2
OSt
Auxiliary output timer 0 Pr2
OSS
Set point for auxiliary output 0 Pr2
OSH
Differential for auxiliary output 2.0 Pr2
OSi
Probe selection for auxiliary output rP Pr2
tdF
Defrost type in Pr2
IdF
Interval between defrost cycles 6.0 Pr2
dtE
Defrost termination temperature
6
Pr2
MdF
Maximum length for defrost
20
Pr2
dFd
Temperature displayed during defrost
set
Pr2
Fdt
Drip time
2
Pr2
dAd
Defrost display time out
20
Pr2
FnC
Fan operating mode o_n Pr2
FSt
Fan stop temperature 15 Pr2
AFH
Differential for the stop temperature and for the alarm 10 Pr2
Fnd
Fan delay after defrost 2 Pr2
ALU
MAXIMUM temperature alarm 30 Pr2
ALL
Minimum temperature alarm
30
Pr2
ALd
Temperature alarm delay
15
Pr2
EdA
Alarm delay after defrost
30
Pr2
tbA
Silencing alarm relay
YES
Pr2
tCy
Duration of last cycle - - - Pr1
tP1
Duration of first phase of the last cycle - - - Pr1
tP2
Duration of second phase of the last cycle - - - Pr1
tP3
Duration of third phase of the last cycle - - - Pr1
Adr
Address for RS485: 1 Pr2
bUt
Buzzer activation at the end of the cycle 30 Pr2
tPb
Type of probe
ntc
Pr2
rEL
Release code (readable only)
2.0
Pr2
Ptb
Parameter code (readable only)
1
Pr2