Cy3: direct fast freezing with holding
CyS =
tEP
iS2
=-18°C
Pd3
= 4
dbC =
no
rS2
=-28°C
dbH = yes
iS1
= -18°C
Pd2
=OFF
HdS = -21°C
rS1
=-30°C
iS3
=-18°C
Pd1
= 4.0
rS3
=-28°C
Cy4: direct fast freezing without holding
CyS = tEP
iS2=-18°C
Pd3 = OFF
dbC = not
rS2=-28°C
dbH = no
iS1 =-18°C
Pd2 =OFF
HdS = OFF
rS1
=-30°C
iS3
=-18°C
Pd1
= 4.0
rS3
=-28°C
26. Standard Values of the parameters
Lab
Description
Values
Level
Set
Set point 3 - - -
Hy
differential 4.0 Pr1
AC
Anti-short cycle delay 2 Pr2
PAU
Time of stand by 20 Pr2
PFt
Maximum acceptable duration of power failure 15 Pr2
Con
Compressor ON time with faulty probe 10 Pr2
COF
Compressor OFF time with faulty probe
10
Pr2
rPO
Thermostat probe calibration
0.0
Pr2
EPP
Evaporator probe presence
YES
Pr2
EPO
Evaporator probe calibration
0.0
Pr2
i1P
Insert probe 1 presence
YES
Pr2
i1o
Insert probe 1 calibration 0.0 Pr2
i2P
Insert probe 2 presence n Pr2
i2o
Insert probe 2 calibration 0 Pr2
i3P
Insert probe 3 presence n Pr2
i3o
Insert probe 3 calibration 0 Pr2
rEM
Probe selection to stop chilling cycle iPt Pr2
CF
Temperature measurement unit
°C
Pr2
rES
Resolution (for °C):
in
Pr2
Lod
Local display
rP
Pr2
rEd
Remote display rP Pr2
d1P
Door switch polarity cL Pr2
Odc
Open door control F-C Pr2
dOA
Open door alarm delay 5 Pr2
dLc
Stop count down of running cycle y Pr2
rrd
Regulation restart after door open alarm Y Pr2
d2F
Second digital input function
EAL
Pr2