7.4. Emptying the dust collecting tank
The dust collection container must be cleaned after a certain number of operating hours. This range
depends on the amount of dust. The dust collecting tank may only be filled up to a maximum of 25%.
The filling level has to be proofed at least once a week.
Whirling up dust is possible due to the polluted filter cartridges!
The filter cartridges must be cleaned before emptying the dust collecting tank.This is done
by carrying out 3 manual cleanings via the unit control (see separate operating
instructions).The filter unit must be switched off beforehand but without disconnecting the
unit from the power supply.After the cleaning, disconnect the filter unit from the power supply
and secure it against being switched on again. After cleaning the filter cartridges wait about
5 minutes before opening the service door.
● Open the service door of the dust collecting housing (see chapter 2.1).
● Resolve the clamping lever (B) of the dust collecting tank (A).
● Carefully pull the dust collecting tank out of the housing.
● Empty the dust collecting tank into an appropriate, closable container or bag. Dispose of or
store the dust according to the regulations.
● Push the dust collecting tank back into the dust collecting housing.
● Manipulate the clamping lever so that the dust collection container is pressed tightly against the
above housing.
● Close the service door.
BA_LFE-101-201-301_220114_EN