EasyManua.ls Logo

Teka LFE 101 - Maintenance Intervals Schedule; Usage-Related Maintenance

Teka LFE 101
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14. Maintenance intervals
14.1. Usage-related maintenance
The described maintenances become necessary through the demands of the system operations. The
maintenance intervals are recommendations. Depending on the application (multi-shift operation, dust
generation, ...) it may make sense for the operator to change the intervals of maintenance, replacing
and cleaning.
Maintenance work must always be documented by means of a protocol.
The approach of the maintenance measures is described in chapter "Maintenance".
Maintenance work
Chapter
Maintenance interval
recommended by TEKA
determined by the operator
Cleaning the filter cartridges
7.2
The cleaning of the filter cartridges is automatically carried out
by the filter unit and thus is not subject to a maintenance interval.
Replacing the filter cartridges
7.3
The saturation of the filter cartridges is automatically monitored
by the filter unit and thus is not subject to a maintenance interval.
The filter unit triggers an alarm when a replacement of the filter
cartridges is necessary.
Replacing the particle filter
7.7
The saturation of the particle filter is automatically monitored by
the filter unit and thus is not subject to a maintenance interval.
The filter unit triggers an alarm when a replacement of the
particle filter is necessary.
Emptying the dust collecting tank (or
check of fill level)
7.4
weekly
Draining the condensate
7.5
monthly
Replacing the activated carbon / the
activated carbon cassette (or check
the degree of pollution)
7.8
when odours occur
Replacing the cooling air filters of the
turbines
7.9
semi-annually
Check / Replacing the filter mat for
the air outlet grille
7.10
semi-annually
BA_LFE-101-201-301_220114_EN