Operating
Instructions
-
FG
5010
7
+/
CLEAR
NOTE
The
CLEAR
key
is
the
only
key
that
will
clear
an
error
in
numeric
entry
.
2-4
ENTER
-
Changes
the
sign
of
the
phase
and
offset
voltages
and
the
exponent
.
A
plus
(
+
)
sign
will
be
assumed
unless
the
button
is
pressed
to
set
a
minus
(
-
)
.
Pressing
the
button
when
minus
(
-
)
is
displayed
changes
the
sign
back
to
plus
(
+
)
.
RECALL
-
Clears
the
entry
being
attempted
and
re
-
displays
the
current
value
of
the
selected
parameter
.
SETUPS
These
two
non
-
illuminated
keys
access
the
ten
available
memory
locations
.
STORE
-
Enters
a
valid
parameter
into
the
current
operating
setup
.
-
This
key
followed
by
one
digit
(
0-9
)
stores
the
last
valid
setup
,
except
in
crement
size
and
GPIB
flags
,
in
its
entirety
,
in
the
desired
memory
location
.
NOTE
Should
the
power
to
the
FG
5010
be
interrupted
for
any
reason
,
all
setups
stored
in
the
memory
will
be
lost
.
SLOPE
-
Recalls
and
activates
the
entire
setup
stored
in
the
selected
memory
location
.
The
contents
of
all
undefined
memory
locations
default
to
power
-
on
settings
.
8
ATRIG
/
GATE
IN
Connector
for
coupling
the
external
trigger
or
gate
signal
to
the
FG
5010
.
NOTE
Input
voltage
limited
to
±
5
V
peak
.
-
Selects
the
slope
(
+
or
-
)
of
the
input
signal
upon
which
the
output
waveform
will
be
triggered
.
Button
is
illuminated
when
+
slope
is
selected
.
9
MAN
TRIG'D
ON
FLASHING
-
Input
triggered
at
greater
than
approximately
a
10
Hz
repetition
rate
or
following
the
input
signal
at
slower
repetition
rates
.
OFF
-
Manual
trigger
control
.
With
no
sig
nal
applied
to
the
TRIG
/
GATE
IN
con
nector
,
provides
one
output
cycle
in
the
TRIG
mode
,
a
burst
of
n
cycles
in
the
BURST
mode
,
or
continuous
out
put
until
the
button
is
released
in
GATE
mode
.
10
A
-
This
indicator
is
active
in
TRIG
,
and
GATE
,
BURST
PH
LOCK
modes
.
It
will
be
in
one
of
the
follow
ing
three
states
.
LOCK'D
Illuminated
when
the
phase
of
the
out
put
waveform
is
locked
to
the
input
trigger
signal
(
PH
LOCK
mode
only
)
.
-
Input
potential
above
threshold
level
with
+
SLOPE
selected
or
below
threshold
level
with
SLOPE
selected
.
Output
deter
mined
by
mode
selected
.
AM
INPUT
With
a
modulating
signal
applied
to
this
connector
,
activation
of
the
AM
function
causes
the
output
waveform
to
be
amplitude
modulated
.
With
no
sig
nal
applied
,
activation
of
this
function
reduces
out
put
amplitude
by
50
%
.
This
button
is
illuminated
when
the
function
is
active
.
FM
-
Input
potential
below
threshold
level
with
+
SLOPE
selected
or
above
threshold
level
with
SLOPE
selected
.
No
output
.
VCF
FM
/
VCF
INPUT
These
two
buttons
are
illuminated
when
the
re
spective
function
is
active
.
These
functions
are
mu
tually
exclusive
.
NOTE
Input
voltage
limited
to
±
11
V
peak
.
-
With
a
modulating
signal
applied
to
the
INPUT
connector
,
activation
of
this
function
causes
the
output
waveform
modulated
.
to
be
frequency
-
With
a
voltage
source
applied
to
the
INPUT
connector
,
activation
of
this
function
causes
the
frequency
of
the
output
waveform
to
be
voltage
controlled
.
A
positive
going
voltage
will
increase
the
frequency
of
the
out
put
signal
.
C
L
U
U
1
U
i
11
U
U

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix FG 5010 and is the answer not in the manual?

Tektronix FG 5010 Specifications

General IconGeneral
BrandTektronix
ModelFG 5010
CategoryPortable Generator
LanguageEnglish

Related product manuals